Verifying Array Support Library (ASL)

Last published : Sep 28, 2026
Make sure that the Array Support Library (ASL) for the array that you add is installed.
To verify Array Support Library (ASL)
  1. If the Array Support Library (ASL) for the array that you add is not installed, obtain and install it on each node before proceeding.
The ASL for the supported storage device that you add is available from the disk array vendor or Veritas technical support.
  1. Verify that the ASL for the disk array is installed on each of the nodes. Run the following command on each node and examine the output to verify the installation of ASL.
The following output is a sample:
\# vxddladm listsupport allLIBNAME             VID                 PID
===========================================================
libvx3par.so        3PARdata            VV
libvxCLARiiON.so    DGC                 All
libvxFJTSYe6k.so    FUJITSU             E6000
libvxFJTSYe8k.so    FUJITSU             All
libvxap.so          Oracle                 All
libvxatf.so         VERITAS             ATFNODES
libvxcompellent.so  COMPELNT            Compellent Vol
libvxcopan.so       COPANSYS            8814, 8818
  1. Scan all disk drives and their attributes, update the VxVM device list, and reconfigure DMP with the new devices. Type:
\# vxdisk scandisks
See the Veritas Volume Manager documentation for details on how to add and configure disks.