Error while performing Exchange post-installation steps
After installing Exchange and rebooting the node, the Veritas High Availability Engine (HAD) may fail to start. As a result, while performing the Exchange post-installation tasks, the Exchange Setup Wizard may either fail to launch or may display the following error message:
Failed to get the cluster information. Make sure that VCS
Engine (HAD) is in running state. Start HAD and click Retry
to continue. Click Cancel to exit the wizard.
Error V-16-13-4207
This issue may occur in a secure cluster environment. (1211491)
To work around this issue
-
Restart the Veritas High Availability Engine (HAD).
Type the following at the command prompt:
hastop -local -force hastart
-
Verify that HAD is running.
Type the following at the command prompt:
hasys -state
The state should display as RUNNING.
-
Click Retry on the Exchange Setup Wizard panel and proceed with the Exchange post-installation steps.