Enabling DMP
These steps assume that InfoScale Storage with the DMP DSMs has been installed.
To enable DMP
-
With SFW on the first server, bring up DMP and include the disks on the storage array and optionally the two direct-attached storage devices. To include each storage array or direct-attached storage device under DMP control:
-
Display the Array Settings screen for the device you are including by doing the following:
-
In the tree view under the Disks icon, select a disk from the storage array.
-
In the right pane, click the Paths tab for the disk. Only one path should display in thePaths tab, since the disk is not yet under DMP control.
-
Right-click the path and select Array Settings from the path context menu that comes up.
-
The Array Settings window comes up. The Exclude checkbox is checked.
-
-
Uncheck the Exclude checkbox.
-
-
Using appropriate cables, connect the second path on Server A to Switch 2.
-
Connect the path through Server A, HBA 2, Channel 2 of the direct-attached storage, and Controller 2 of the large storage array.
-
Complete any necessary configuration of the switch.
-
-
Go to Actions and selectRescan to verify that twopaths are shown under the Paths tab. This indicates that one set of disks has two paths and that DMP DSMs is installed correctly.
-
Complete step 1 to step 3 on Server B.
Microsoft clustering and DMP are now set up, and the upgraded configuration steps are complete.